3D visualization
VYBO Electric
Model | V810-4T0040 |
Power | 4 kW |
Nominal output current | 9 A |
Input voltage 50/60Hz | 3 Phases 400V |
Output voltage 50/60Hz | 3 Phases 400V |
Power cable cross section | 1,5 mm² |
Brake unit | Yes |
If you have any questions, please do not hesitate to contact us:
100% safe payment
3D visualization
VYBO Electric
Variable frequency drive 4kW 400V V810-4T0040 is in stock. The V810 series variable frequency drives (4kW) have been specifically developed for the most demanding and complex professional applications. These vector frequency converters are versatile and can withstand high loads. With an overload capability of up to 180% for 3 seconds and 150% for 60 seconds, they belong to the highest class of mass-produced variable frequency drives, capable of up to 1000kW. Their construction is designed to withstand enormous loads, making them ideal for heavy-duty applications.
With its versatile configurations and numerous additional options, the V810 series offers a wide range of capabilities, allowing a single platform to cover different requirements. This flexibility makes them suitable for use in all industries and is suitable for both simple and very demanding applications.
The 4kW V810 400V inverters belong to the heavy-duty category and are particularly suitable for environments with demanding conditions and higher overload capability. More detailed information about these exceptional devices can be found in the data sheet or other documentation. On this page we provide comprehensive user manuals and a catalog of variable frequency drives (in PDF format). If you have any questions, our dedicated customer hotline and contact email are available and our knowledgeable staff will be happy to assist you.
Product specifications
Model: V810 Series
Power: 4kW
Overload capacity:
180% for 3 seconds
150% for 60 seconds
Scope of application:
Textile production
Energy industry
Mining industry
automotive industry and others
To further improve our customer experience, we offer comprehensive support materials. Our user manuals provide step-by-step instructions for the efficient installation and operation of the V810 series inverters. Additionally, our frequency inverter catalog provides an overview of our extensive product range and demonstrates the versatility and adaptability of our inverters to various industry requirements.
At VYBO Electric, we attach great importance to customer satisfaction. We understand that selecting the right variable frequency drive for your specific needs can be a complex task. That’s why our team of experts is available to answer your questions or concerns via our customer hotline and contact email. We are committed to providing tailored solutions that meet the unique needs of your industry.
We value your trust in our products and are committed to delivering reliable, high-performance variable frequency drives for your professional applications. Work with us and experience the exceptional performance and versatility of the V810 400V series frequency converter. Contact us today to learn more and discuss how our solutions can strengthen your business.
In addition to our extensive range of high quality variable speed drives, we are pleased to offer a convenient and efficient delivery service to our customers throughout the United Kingdom. We know how important timely and reliable shipping is, especially when it comes to industrial equipment and components. When you place an order with us, our dedicated logistics team will ensure that your products are carefully packaged and prepared for safe transport. We work with trusted shipping partners who specialize in handling delicate and heavy equipment and guarantee that your order will arrive in excellent condition.
If you have any questions or concerns regarding the delivery of your order to the United Kingdom, our customer support team is available to assist you at any time. Whether you need information about shipping costs, estimated delivery times or other questions, we are committed to providing you with a prompt and helpful response.
At VYBO Electric, our commitment to customer satisfaction goes beyond the quality of our products. Our aim is to provide a comprehensive and reliable service from the order to the successful receipt of your Variable frequency drive in United Kingdom. Trust us to handle your converter needs professionally and efficiently, so you can focus on your core business activities. Contact our customer support team today to discuss your requirements and find out how we can help you obtain the high-performance frequency converters you need for your industrial applications in the United Kingdom.
Inverter model type V810 | Rated power (kW). | Nominal input current (A) | Rated output current (A) | Recommended motor power (kW) |
V810-4T0040 | 4,0 | 10 | 9 | 4,0 |
Input voltage (V) 50/60 Hz | Motor power (kW) | Recommended cable cross section (mm²) | Recommended circuit breaker (A) | |
3 phases 3×400 V | 4,0 | 2,5 | 16 |
Table of suitable braking resistors
Frequency inverter type | Brake resistor | Brake unit | Brake torque (10% ED) | Recommended motor power (kW) | |
Resistance power (W) | Resistance value (Ω) (≥) | ||||
V810-4T0040 | 300 | 130 | Built-in | 125 | 4,0 |
General technical parameters for all V810 types
Element | VECTOR V810 | |
---|---|---|
Performance | Power supply | Input voltage range: 1 x 230V AC ± 15% 3 x 400 V AC ± 15% 3 x 690V AC ± 15% Supply frequency range: 47 to 63 Hz |
Standard functions | Control mode | V/F scalar control SFVC idle vector CLVC vector control |
Maximum frequency | SFVC, CLVC vector control: 0 – 300 Hz V/F scalar control: 0 – 3200 Hz |
|
Carrier frequency | 1-16 kHz The carrier frequency is automatically set based on the load characteristics. |
|
Input frequency resolution | Digital setting 0.01 Hz Analogue setting: maximum frequency x 0.025% |
|
Initial torque | G-Type: 0.5 Hz/150% (SVFC) G-Type: 0.5 Hz /180% (CLVC) P-Type: 0.5Hz/100% (V/F). |
|
Speed range | 1:100 (SFVC) 1:1000 (CLVC) |
|
Speed stability | ± 0.5% (SFVC) ± 0.02% (CLVC) |
|
Precise torque control | ± 5% (CLVC) | |
Overload capacity | G type: 60s for 150% of rated current, 3s for 180% of rated current P-Type: 60s for 120% of rated current, 3s for 150% of rated current. |
|
Torque increase | Auto boost or custom boost from 0.1% to 30.0% | |
V/F curve | Linear V/F curve Multipoint V/F curve N-voltage V/F curve (multiple of 1.2-voltage, 1.4-voltage, 1.6-voltage, 1.8-voltage, modified) |
|
V/F separation | Two types: complete separation; half separation | |
Ramp modes | Linear ramp S-curve ramp Four groups of acceleration/deceleration times with a range of 0.0-6500.0 s |
|
Input and output | Input terminal blocks | 8 digital inputs, ON/OFF binary inputs, 1 terminal X5 can support high speed pulse inputs. All ports have selectable PNP or NPN outputs 2 analog inputs, one of which supports FIV -10 V / +10 V; or 0-10V input and the second FIC supports 0-10V or 0-20mA (4-20mA) input. |
Output terminal blocks | 1 Programmable Open Collector Output: Provides 1 output port (open collector output or high speed pulse output) 2 relay outputs, 2 analog outputs: FOV and FOC with selectable 0-20mA (4-20mA) or 0-10V output | |
PG | PG cards | The converter is equipped with a connector for PG cards (for encoders) or PG cards for use with a resolver, etc. |
Standard functions | DC braking | Brake frequency: 0.0 Hz to maximum frequency Braking time: 0.0-36.0s Current value when braking: 0.0%-100.0% |
Brake unit | Models up to 18.5 kW have a built-in braking unit as standard. | |
Control in JOG mode (step operation) | JOG frequency range: 0.00-50.00 Hz JOG acceleration/deceleration time: 0.0-6500.0 s |
|
Implement. more preset speeds | Up to 16 speeds implemented via a simple PLC function or a combination of X end states. | |
PTC/thermal contact | Input for PTC motor or thermal contact protection. | |
Built-in PID controller | Enables a process-controlled closed-loop control system. | |
AVR automatic voltage regulation | It can automatically maintain a constant output voltage when the supply voltage changes. | |
Overvoltage and overcurrent regulator | Current and voltage are automatically limited during operation to prevent frequent shutdowns due to over-voltage and over-current. | |
Torque and steering limitation | It can automatically limit the torque and prevent frequent overcurrent changes during operation. | |
Safety function EMS STOP | The “Emergency Stop” system: In emergencies, the inverter stops immediately after EMS STOP is activated. | |
Fast current limitation | Prevents common faults due to overcurrent on AC motor | |
High performance | The control of the AC motor is carried out by the powerful current vector control technology. | |
Time management | Time range: 0.0-6500.0 minutes | |
Communication | MODBUS RTU, PROFIBUS-DP (from 5.5 kW) | |
Execute command channel | Depending on the panel, control terminals, the serial communication port can be switched in many ways | |
Frequency source | 10 kinds of frequencies, given by digital analog voltage, analog current, pulse, serial port, X8, PID, can be switched in many ways | |
Auxiliary frequency source | 10 kinds of frequencies, micro adjustment can be easily realized, frequency synthesizer | |
LED display | Displays parameters | |
Key lock and function selection | It can partially or completely lock keys and set the functionality of some keys to prevent malfunction. | |
Protection mode | Motor short circuit detection at power-on, output phase loss protection, over-current protection, over-voltage protection, under-voltage protection, over-temperature protection and overload protection. | |
EMC (compactability) | IEC 61000-4-6; IEC 61000-4-4; IEC 61000-4-11; IEC 61000-4-5 | |
Standards | EN/IEC 61800-3: 2017; C1, which is suitable for the 1st environment; EN/IEC 61800-3: 2017; C2, which is suitable for the 1st environment; |
|
Environmental installation | Install indoors, avoid direct sunlight, salt, dust, corrosive or flammable gases, smoke and steam. Resistance to chemical pollution, class 3C3 EN/IEC 60721-3-3. Resistance to dust pollution 3S3EN/IEC 60721-3-3. |
|
Alt. Height. | Below 1000 meters above sea level. (Reduce the power level when used above 1000 meters above sea level.) | |
Ambient temperature | -10°C ~ 40°C (reduce the power level when the ambient temperature is between 40°C and 50°C) | |
Humidity | Less than 95% relative humidity, non-condensing IEC 60068-2-3 |
|
Vibrations | Less than 5.9 m/s2 (0.6 g) IEC 60068-2-6 | |
Storage temperature | -20°C ~60°C |
1PH / 3PH AC 230V ±15% | ||||
Inverter model type V810 | Rated power (kW) | Maximum input current (A) | Rated output current (A) | Recommended motor power (kW) |
V810-2S0004 | 0,4 | 5.4 | 2.4 | 0,4 |
V810-2S0007 | 0,75 | 7.2 | 4,5 | 0,75 |
V810-2S0015 | 1,5 | 10 | 7 | 1,5 |
V810-2S0022 | 2.2 | 16 | 10 | 2.2 |
V810-2S0030 | 3 | 23 | 16 | 3 |
3PH / 3PH AC 400 V ±15 % | ||||
V810-4T0004 | 0,4 | 3,4 | 1,2 | 0,4 |
V810-4T0007 | 0,75 | 3,8 | 2,5 | 0,75 |
V810-4T0015 | 1,5 | 5 | 3.7 | 1,5 |
V810-4T0022 | 2.2 | 5.8 | 5 | 2.2 |
V810-4T0040 | 4 | 10 | 9 | 4 |
V810-4T0055 | 5,5 | 15 | 13 | 5,5 |
V810-4T0075 | 7,5 | 19 | 17,5 | 7,5 |
V810-4T0110 | 11 | 26 | 25 | 11 |
V810-4T0150 | 15 | 35 | 32 | 15 |
V810-4T0220 | 22 | 46 | 45 | 22 |
V810-4T0300 | 30 | 62 | 60 | 30 |
V810-4T0370 | 37 | 76 | 75 | 37 |
V810-4T0370 | 37 | 76 | 75 | 37 |
V810-4T0450 | 45 | 90 | 90 | 45 |
V810-4T0550 | 55 | 105 | 110 | 55 |
V810-4T0750 | 75 | 140 | 150 | 75 |
V810-4T0900 | 90 | 160 | 176 | 90 |
V810-4T1100 | 110 | 210 | 210 | 110 |
V810-4T1320 | 132 | 240 | 253 | 132 |
V810-4T1600 | 160 | 290 | 300 | 160 |
V810-4T1850 | 185 | 330 | 340 | 185 |
V810-4T2000 | 200 | 370 | 380 | 200 |
V810-4T2200 | 220 | 410 | 420 | 220 |
V810-4T2500 | 250 | 460 | 470 | 250 |
V810-4T2800 | 280 | 500 | 520 | 280 |
V810-4T3150 | 315 | 580 | 600 | 315 |
V810-4T3550 | 355 | 620 | 640 | 355 |
V810-4T4000 | 400 | 670 | 690 | 400 |
V810-4T4500 | 450 | 790 | 790 | 450 |
V810-4T5000 | 500 | 835 | 860 | 500 |
V810-4T5600 | 560 | 920 | 950 | 560 |
V810-4T6300 | 630 | 1050 | 1100 | 630 |
V810-4T7100 | 710 | 1126 | 1280 | 710 |
V810-4T8000 | 800 | 1460 | 1380 | 800 |
V810-4T9000 | 900 | 1640 | 1640 | 900 |
V810-4T10000 | 1000 | 1800 | 1720 | 1000 |
V810-4T11000 | 1100 | 1890 | 1920 | 1100 |
Input voltage (V) 50/60 Hz | Motor power (kW) | Recommended cable cross section (mm²) | Recommended circuit breaker (A) | Recommended input contactor (A) | |
V810-2S0004 | 1 Phase 1×230 V | 0,4 | 1,5 | 10 | 9 |
V810-2S0007 | 0,75 | 1,5 | 16 | 12 | |
V810-2S0015 | 1,5 | 2,5 | 25 | 18 | |
V810-2S0022 | 2.2 | 4 | 32 | 25 | |
V810-2S0030 | 3 | 6 | 40 | 32 | |
V810-4T0004 | 3 Phases 3×400 V | 0,4 | 1,5 | 6 | 9 |
V810 -4T0007 | 0,75 | 1,5 | 6 | 9 | |
V810-4T0015 | 1,5 | 1,5 | 10 | 9 | |
V810-4T0022 | 2.2 | 1,5 | 10 | 9 | |
V810-4T0040 | 4 | 2,5 | 16 | 12 | |
V810-4T0055 | 5,5 | 2,5 | 20 | 18 | |
V810-4T0075 | 7,5 | 4 | 32 | 25 | |
V810-4T0110 | 11 | 4 | 32 | 25 | |
V810-4T0150 | 15 | 6 | 40 | 32 | |
V810-4T0185 | 18,5 | 10 | 50 | 38 | |
V810-4T0220 | 22 | 10 | 50 | 40 | |
V810-4T0300 | 30 | 16 | 63 | 50 | |
V810-4T0370 | 37 | 25 | 100 | 65 | |
V810-4T0450 | 45 | 25 | 100 | 80 | |
V810-4T0550 | 55 | 35 | 125 | 95 | |
V810-4T0750 | 75 | 50 | 160 | 115 | |
V810-4T0900 | 90 | 70 | 225 | 170 | |
V810-4T1100 | 110 | 95 | 250 | 205 | |
V810-4T1320 | 132 | 120 | 315 | 245 | |
V810-4T1600 | 160 | 120 | 350 | 300 | |
V810-4T1850 | 185 | 150 | 400 | 300 | |
V810-4T2000 | 200 | 185 | 500 | 410 | |
V810-4T2200 | 220 | 185 | 500 | 410 | |
V810-4T2500 | 250 | 240 | 630 | 475 | |
V810-4T2800 | 280 | 240 | 630 | 475 | |
V810-4T3150 | 315 | 240 | 800 | 620 | |
V810-4T3500 | 350 | 2×150 | 800 | 620 | |
V810-4T4000 | 400 | 2×185 | 1000 | 800 | |
V810-4T4500 | 450 | 2×240 | 1250 | 800 | |
V810-4T5000 | 500 | 2×240 | 1250 | 1000 |
Table of suitable braking resistors V810
Frequency converter type | Brake resistor | Brake unit | Brake torque (10% ED) | Recommended motor power (kW) | |
Resistance power (W) | Resistance value (Ω) (≥) | ||||
V810-2S0004 | 80 | 200 | Built-in | 125 | 0,4 |
V810-2S0007 | 80 | 150 | Built-in | 125 | 0,75 |
V810-2S0015 | 100 | 70 | Built-in | 125 | 1,5 |
V810-2S0022 | 100 | 70 | Built-in | 125 | 2.2 |
V810-2S0030 | 250 | 65 | Built-in | 125 | 3 |
V810-4T0004 | 150 | 300 | Built-in | 125 | 0,4 |
V810-4T0007 | 150 | 300 | Built-in | 125 | 0,75 |
V810-4T0015 | 150 | 220 | Built-in | 125 | 1,5 |
V810-4T0022 | 250 | 200 | Built-in | 125 | 2.2 |
V810-4T0055 | 300 | 130 | Built-in | 125 | 5,5 |
V810-4T0075 | 0,5 | 65 | Built-in | 125 | 7,5 |
V810-4T0110 | 0,5 | 65 | Built-in | 125 | 11 |
V810-4T0150 | 0,80 | 43 | Built-in | 125 | 15 |
V810-4T0185 | 1 | 32 | Built-in | 125 | 18,5 |
V810-4T0220 | 1.3 | 25 | Optional (integrated) | 125 | 22 |
V810-4T0300 | 1,5 | 22 | Optional (integrated) | 125 | 30 |
V810-4T0370 | 2,5 | 16 | Optional (integrated) | 125 | 37 |
V810-4T0450 | 3.7 | 12.6 | Optional (integrated) | 125 | 45 |
V810-4T0550 | 4,5 | 9.4 | Optional (integrated) | 125 | 55 |
V810-4T0750 | 5,5 | 9.4 | Optional (integrated) | 125 | 75 |
V810-4T0900 | 7,5 | 6.3 | External | 125 | 90 |
V810-4T1100 | 4,5 x 2 | 9,4 x 2 | External | 125 | 110 |
V810-4T1320 | 5,5 x 2 | 9,4 x 2 | External | 125 | 132 |
V810-4T1600 | 6,5 x 2 | 6,3 x 2 | External | 125 | 160 |
V810-4T1850 | 16 | 2,5 | External | 125 | 185 |
V810-4T2000 | 6,5 x 3 | 6,3 x 3 | External | 125 | 200 |
V810-4T2500 | 22000 | 2,5 | External | 125 | 250 |
V810-4T3150 | 16000*2 | 2,5 x 2 | External | 125 | 315 |
V810-4T3550 | 17000*2 | 2,5 x 2 | External | 125 | 355 |
V810-4T4000 | 14000*3 | 2,5 x 3 | External | 125 | 400 |
V810-4T4500 | 15000*3 | 2,5 x 3 | External | 125 | 450 |
V810-4T5000 | 17000*3 | 2,5 x 3 | External | 125 | 500 |
V810-4T5600 | 20000*3 | 2,5 x 3 | External | 125 | 560 |
V810-4T6300 | 22000*3 | 2,5 x 3 | External | 125 | 630 |
V810-4T7100 | 20000*4 | 2,5 x 4 | External | 125 | 710 |
V810-4T8000 | 20000*4 | 2,5 x 4 | External | 125 | 800 |
V810-4T9000 | 22000*4 | 2,5 x 4 | External | 125 | 900 |
V810-4T10000 | 20000*5 | 2,5 x 5 | External | 125 | 1000 |
V810-4T11000 | – | – | External | – | 1100 |
Rated power | 4,0 kW |
Nominal output current | 9 A |
Supply voltage | 3 x 400 V |
Output voltage | 0 – 400 V |
Output frequency | 0 – 3200 Hz |
Overload capability in ND mode – Normal Duty | 120% / 60s |
Overload in HD mode – Heavy Duty (Heavy Duty) | 150% / 60s |
Control mode V/F scalar control | ✓ |
SFVC open loop vector control mode | ✓ |
CLVC closed loop vector control mode | ✓ |
Analog inputs | 2 |
Digital inputs | 8 |
Analog outputs | 2 |
Relay outputs | 2 |
Open collector outputs | 1 |
Integrated brake transistor | ✓ |
EMC filter | ✓ |
+10V output | ✓ |
+24 V output | ✓ |
Input for PTC | ✓ |
Safe torque off (STO) | X |
Emergency stop (EMS) | ✓ |
Integrated Ethernet | X |
Integrated MODBUS RTU | ✓ |
PROFIBUS | ✓ |
PG card for encoder | ✓ |
PID | ✓ |
Intelligent PLC function | ✓ |
External panel connection (typically up to 30 m) | ✓ |
Protection class IP 20 | ✓ |
Protection class IP 65 | X |
Change direction of rotation via external input | ✓ |
Change direction of rotation in the control panel | ✓ |