3D visualization
VYBO Electric
Model | V900-4T0007 |
Power | 0,75 kW |
Max. Input current | 3,8 A |
Nominal output current | 2,5 A |
Suitable motor | 0,75 kW |
Power cable cross section | 1,5 mm² |
Protection | 6 A |
Brake unit | No |
EMC filter | Yes |
172,00 £
In StockIf you have any questions, please do not hesitate to contact us:
100% safe payment
3D visualization
VYBO Electric
Variable speed drive 0,75kW 400V V900-4T0007 in stock. Variable speed drives (VSDs) from VYBO Electric – a reliable and versatile solution for your motor control needs. With a power of 0,75kW and a voltage of 400V, this VFD is designed to deliver outstanding performance and efficiency in various applications across the United Kingdom, from busy cities such as London, Glasgow and Birmingham to industrial centers such as Leeds and Edinburgh.
The 0,75kW variable speed drive 400V V900 offers a wide supply frequency range of 47 to 63 Hz, enabling compatibility with various power systems. It has a maximum frequency of 0 to 600 Hz, allowing precise control of motor speed and operation. With a speed range of 1:100 (SVC) or 1:1000 (CLVC), you have the flexibility to achieve the desired output speed for your specific application. Equipped with advanced features such as automatic torque increase or user-defined increase in the range of 0.1% to 30%, the V900 series ensures optimal engine performance and efficiency. The built-in PID controller enables a process-controlled control system that enables precise control of motor speed and torque.
We deliver 0,75kW V900 variable speed drive quickly throughout the United Kingdom. One of the main advantages of the V900 series is its ability to automatically maintain a constant output voltage even when the supply voltage fluctuates. This ensures stable and reliable operation, protects your devices and improves overall system performance. By using powerful current vector control technology, the V900 series enables precise control of AC motor operation. It supports various input options including PG card differential input, PG card resolver and PG card rotary transformer, providing versatility and compatibility with different motor types.
At VYBO Electric, we are committed to providing our customers with competitive pricing and exceptional service. You can purchase the 0,75kW variable speed drive V900 in our online e-shop at an extremely reasonable price. We offer a wide range of variable speed drives and our extensive stock ensures fast delivery to cities across the United Kingdom. We pride ourselves on delivering high quality products that are built to last and perform reliably.
To provide a complete drive system solution, we offer a range of accessories and supplementary products in our e-shop, including electric motors, worm gears, inlet throttles and pressure sensors. Our user-friendly e-shop makes it easy to browse and select the products you need, and our secure checkout process ensures a seamless shopping experience. Discover the benefits of the V900 Series 0,75kW 400V AC drive and experience the difference it can make in your motor control applications. Order today and benefit from our fast delivery and customer-oriented service. Trust VYBO Electric for all your motor control needs and join our growing community of satisfied customers.
With the V900 series variable speed drive, you can achieve energy savings, precise motor control and higher operating efficiency. Whether you work in manufacturing, HVAC systems, water treatment plants, or any other industry where motor control is required, the V900 Series offers the versatility and reliability you need. Experience the power of VYBO Electric’s V900 VFD and unlock the full potential of your motor-driven applications. Trust our expertise, quality products and efficient delivery to support your business success. Order your 0,75kW V900 frequency converter today.
Inverter model type V900 | Rated power (kW). | Nominal input current (A) | Rated output current (A) | Recommended engine power (kW) |
V900-4T0007 | 0,75 | 3,8 | 2,5 | 0,75 |
Input voltage (V) 50/60 Hz | Motor power (kW) | Recommended cable cross section (mm²) | Recommended circuit breaker (A) | |
3 phases 3×400 V | 0,75 | 1,5 | 6 |
Table of suitable braking resistors
Frequency converter type | Brake resistor | Brake unit | Recommended motor power (kW) | |
Resistance power (W) | Resistance value (Ω) (≥) | |||
V900-4T0007 | 250 | 300 | 250W-300R | 0,75 |
General technical parameters for all V900 types
Power | Input voltage range: 1 x 230 V AC ± 10% Input voltage range: 3 x 400 V AC ± 10% |
Input frequency | Power supply frequency range: 47 to 63 Hz |
Control mode | V/F scalar control SFVC open loop vector control CLVC closed loop vector control (over 4kW) |
Maximum frequency | 0 – 600 Hz |
Carrier frequency | 0.5 kHz – 8 kHz The carrier frequency is automatically set based on the load characteristics. |
Resolution of the input frequency | Digital setting 0.01 Hz Analogue setting: maximum frequency x 0.025% |
Initial torque | G type: 0.5 Hz / 150% (SFVC) G type: 0.5 Hz / 180% (CLVC) P type: 0.5 Hz / 100% |
Speed range | 1:100 (SVC) 1:1000 (CLVC) |
Speed stability | ± 0.5% (SFVC) ± 0.2% (CLVC) |
Overload capacity | G type: 60s for 150% of rated current, 3s for 180% of rated current P-Type: 60s for 120% of rated current, 3s for 150% of rated current. |
Torque increase | Auto boost or custom boost from 0.1% to 30.0% |
V/F curve | Straight V/F curve Multipoint V/F curve N-voltage V/F curve (multiple of 1.2-voltage, 1.4-voltage, 1.6-voltage, 1.8-voltage, modified) |
V/F separation | Two types: complete separation; half separation |
Ramp modes | Linear ramp Four groups of acceleration/deceleration times with a range of 0.0-6500.0 s |
DC braking | Brake frequency: 0.0 Hz to maximum frequency Braking time: 0.0-36.0s Current value when braking: 0.0%-100.0% |
Control in JOG mode | JOG frequency range: 0.00-50.00 Hz JOG acceleration/deceleration time: 0.0-6500.0 s |
Simple PLC, multiple preset speeds | Up to 16 speeds implemented via a simple PLC function or a combination of X end states |
Built-in PID controller | Enables a process-controlled closed-loop control system. |
AVR automatic voltage regulation | maintained when the supply voltage changes |
Overvoltage and overcurrent regulator | Current and voltage are automatically limited during operation to prevent frequent shutdowns due to over-voltage and over-current |
Fast current limitation | Prevents common faults due to overcurrent on AC motor |
Torque and steering limitation | It can automatically limit the torque and prevent the overcurrent from changing frequently during operation. Torque control can be implemented in CLVC mode. |
High performance | The control of the AC motor is carried out by the powerful current vector control technology. |
Support for PG card | Support PG card differential input, PG card resolver, PG card rotary transformer… |
Safety function STO | “Emergency Stop” system: In emergencies, it stops the inverter immediately after the switch J4 is activated to STO. |
PTC motor warm-up test | Input for thermal PTC motor protection. |
Time management | Time range: 0.0-6500.0 minutes |
Communication protocol | MODBUS RTU, PROFINET |
Execute command channel | Control panel / control terminals / serial communication port You can switch between these sources in different ways |
Frequency source | 10 kinds of frequencies. Setting via digital, analog voltage, analog current, pulse, serial interface. You can switch between these sources with various specials. |
Auxiliary frequency source | 10 kinds of frequencies. Allows you to fine-tune the auxiliary frequency and frequency synthesis. |
Input terminal blocks | 5 digital inputs for 0.4 – 5.5 kW models 1 analog input for models up to 0.4 – 5.5 kW 6 digital inputs for models over 7.5 kW 2 analog inputs for models over 7.5 kW |
Output terminal blocks | 1 high speed pulse output (open collector) 1 relay output terminal for 0.4-5.5 kW models 1 analog output port for 0.4-5.5 kW models 2 output relay terminals for 7.5 – 500 kW models 2 analog output terminals for power 7.5 – 500 kW 1 high speed pulse output (open collector) |
EMC (compactability) | IEC 61000-4-6; IEC 61000-4-4; IEC 61000-4-11; IEC 61000-4-5 |
Standards | EN/IEC 61800-3: 2017; C1, which is suitable for the 1st environment; EN/IEC 61800-3: 2017; C2, which is suitable for the 1st environment; |
LED display | Displays parameters |
Key lock and function selection | It can partially or completely lock keys and set the functionality of some keys to prevent malfunctions |
Protection mode | Motor short circuit detection at power-on, output phase loss protection, over-current protection, over-voltage protection, under-voltage protection, over-temperature protection and overload protection. |
Environmental installation | Install indoors, avoid direct sunlight, salt, dust, corrosive or flammable gases, smoke and steam. Resistance to chemical pollution, class 3C3 EN/IEC 60721-3-3. Resistance to dust pollution 3S3EN/IEC 60721-3-3. |
Alt. Height. | Below 1000 meters above sea level. (Reduce the power level when used above 1000 meters above sea level.) |
Ambient temperature | -10°C – 40°C (reduce the power level when the ambient temperature is between 40°C and 50°C) |
Humidity | Less than 95% relative humidity, non-condensing IEC 60068-2-3 |
Vibrations | Less than 5.9 m/s2 (0.6 g) IEC 60068-2-6 |
Storage temperature | -20°C to + 60°C |
1PH / 3PH AC 230V ±15% | ||||
Inverter model type V900 | Rated power (kW) | Maximum input current (A) | Rated output current (A) | Recommended motor power (kW) |
V900-2S0004 | 0,4 | 5,4 | 2,5 | 0,4 |
V900-2S0007 | 0,75 | 7,2 | 5 | 0,75 |
V900-2S0015 | 1,5 | 10 | 7 | 1,5 |
V900-2S0022 | 2,2 | 16 | 10 | 2,2 |
V900-2S0030 | 3 | 17 | 16,5 | 3 |
3PH / 3PH AC 400 V ±15 % | ||||
V900-4T0007 | 0,75 | 3,8 | 2,5 | 0,75 |
V900-4T0015 | 1,5 | 5 | 3,7 | 1,5 |
V900-4T0022 | 2,2 | 5,8 | 5 | 2,2 |
V900-4T0030 | 3 | 7,9 | 7,5 | 3 |
V900-4T0040 | 4 | 10 | 9 | 4 |
V900-4T0055 | 5,5 | 15 | 13 | 5,5 |
V900-4T0075 | 7,5 | 20 | 17 | 7,5 |
V900-4T0110 | 11 | 26 | 25 | 11 |
V900-4T0150 | 15 | 35 | 32 | 15 |
V900-4T0185 | 18,5 | 38 | 37 | 18,5 |
V900-4T0220 | 22 | 46 | 45 | 22 |
V900-4T0300 | 30 | 62 | 60 | 30 |
V900-4T0370 | 37 | 76 | 75 | 37 |
V900-4T0450 | 45 | 90 | 90 | 45 |
V900-4T0550 | 55 | 113 | 110 | 55 |
V900-4T0750 | 75 | 157 | 150 | 75 |
V900-4T0900 | 90 | 180 | 176 | 90 |
V900-4T1100 | 110 | 214 | 210 | 110 |
V900-4T1320 | 132 | 256 | 253 | 132 |
V900-4T1600 | 160 | 307 | 300 | 160 |
V900-4T1850 | 185 | 355 | 340 | 185 |
V900-4T2000 | 200 | 385 | 380 | 200 |
V900-4T2200 | 220 | 430 | 420 | 220 |
V900-4T2500 | 250 | 475 | 470 | 250 |
V900-4T2800 | 280 | 525 | 520 | 280 |
V900-4T3150 | 315 | 610 | 600 | 315 |
V900-4T3500 | 350 | 665 | 640 | 350 |
V900-4T4000 | 400 | 700 | 690 | 400 |
V900-4T4500 | 450 | 800 | 790 | 450 |
V900-4T5000 | 500 | 865 | 860 | 500 |
Input voltage (V) 50/60 Hz | Motor power (kW) | Recommended cable cross section (mm²) | Recommended circuit breaker (A) | Recommended input contactor (A) | |
V900-2S0004 | 1×230 V 50/60 Hz | 0,4 | 1,5 | 10 | 9 |
V900-2S0007 | 0,75 | 1,5 | 16 | 12 | |
V900-2S0015 | 1,5 | 1,5 | 25 | 18 | |
V900-2S0022 | 2,2 | 2,5 | 32 | 25 | |
V900-2S0030 | 3 | 2,5 | 40 | 32 | |
V900-4T0007 | 3×400 V 50/60 Hz | 0,75 | 1,5 | 6 | 9 |
V900-4T0015 | 1,5 | 1,5 | 10 | 9 | |
V900-4T0022 | 2,2 | 1,5 | 10 | 9 | |
V900-4T0030 | 3 | 1,5 | 16 | 12 | |
V900-4T0040 | 4 | 1,5 | 16 | 12 | |
V900-4T0055 | 5,5 | 1,5 | 16 | 12 | |
V900-4T0075 | 7,5 | 2,5 | 20 | 18 | |
V900-4T0110 | 11 | 4 | 32 | 25 | |
V900-4T0150 | 15 | 4 | 40 | 32 | |
V900-4T0185 | 18,5 | 6 | 50 | 38 | |
V900-4T0220 | 22 | 10 | 80 | 65 | |
V900-4T0300 | 30 | 10 | 80 | 65 | |
V900-4T0370 | 37 | 16 | 100 | 65 | |
V900-4T0450 | 45 | 25 | 100 | 80 | |
V900-4T0550 | 55 | 35 | 160 | 95 | |
V900-4T0750 | 75 | 50 | 160 | 115 | |
V900-4T0900 | 90 | 70 | 250 | 150 | |
V900-4T1100 | 110 | 95 | 250 | 170 | |
V900-4T1320 | 132 | 120 | 400 | 205 | |
V900-4T1600 | 160 | 150 | 400 | 245 | |
V900-4T1850 | 185 | 185 | 400 | 300 | |
V900-4T2000 | 200 | 185 | 500 | 410 | |
V900-4T2200 | 220 | 185 | 500 | 410 | |
V900-4T2500 | 250 | 240 | 630 | 410 | |
V900-4T2800 | 280 | 240 | 630 | 475 | |
V900-4T3150 | 315 | 150*2 | 700 | 620 | |
V900-4T3500 | 350 | 185*2 | 800 | 620 | |
V900-4T4000 | 400 | 185*2 | 800 | 620 | |
V900-4T4500 | 450 | 240*2 | 1000 | 800 | |
V900-4T5000 | 500 | 240*2 | 1000 | 800 |
Table of suitable braking resistors V900
Models with 1 x 230 V power supply (V900-2S….) | |||||
Brake unit | Model | Power (kW) | Marker | Brake resistor | |
Resistance power (W) | Resistance value (Ω) (≥) | ||||
No | V900-2S0004 | 0,4 | 80W-200R | 80 | 200 |
V900-2S0007 | 0,75 | 80W-150R | 80 | 150 | |
V900-2S0015 | 1,5 | 100W-50R | 100 | 100 | |
V900-2S0022 | 2,2 | 100W-50R | 100 | 70 | |
V900-2S0030 | 3 | 250W-65R | 250 | 65 | |
Models with 3 x 400 V power supply (V900-4T….) | |||||
Brake unit | Model | Power (kW) | Marker | Brake resistor | |
Resistance power (W) | Resistance value (Ω) (≥) | ||||
No | V900-4T0007 | 0,75 | 250W-300R | 250 | 300 |
V900-4T0015 | 1,5 | 300W-220R | 300 | 220 | |
V900-4T0022 | 2,2 | 400W-200R | 400 | 200 | |
V900-4T0030 | 3,0 | 500W-150R | 500 | 150 | |
V900-4T0040 | 4,0 | 500W-130R | 500 | 130 | |
V900-4T0055 | 5,5 | 500W-130R | 500 | 130 | |
Yes | V900-4T0075 | 7,5 | 800W-90R | 800 | 90 |
V900-4T0110 | 11 | 1000W-65R | 1000 | 65 | |
V900-4T0150 | 15 | 1500W-43R | 1500 | 43 | |
V900-4T0185 | 18,5 | 2000W-32R | 2000 | 32 | |
V900-4T0220 | 22 | BRU-4KW-24R | 4000 | 24 | |
V900-4T0300 | 30 | BRU-4.5KW-24R | 4500 | 24 | |
V900-4T0370 | 37 | BRU-6KW-19.2R | 6000 | 19,2 | |
Possibility | V900-4T0450 | 45 | BRU-7KW-14.8R | 7000 | 14,8 |
V900-4T0550 | 55 | BRU-9KW-12.8R | 9000 | 12,8 | |
V900-4T0750 | 75 | BRU-11KW-9.6R | 11000 | 9,6 | |
V900-4T0900 | 90 | BRU-15KW-6.8R | 15000 | 6,8 | |
V900-4T1100 | 110 | BRU-9KW-9.3R*2 | 9000*2 | 9,3*2 | |
V900-4T1320 | 132 | BRU-13KW-9.3R*2 | 13000*2 | 9,3*2 | |
V900-4T1600 | 160 | BRU-13KW-6.2R*2 | 13000*2 | 6,2*2 | |
V900-4T1850 | 185 | BRU-16KW-6.2R*2 | 16000*2 | 6,2*2 | |
V900-4T2000 | 200 | BRU-19KW-2.5R*2 | 19000*2 | 2,5*2 | |
V900-4T2200 | 220 | BRU-19KW-2.5R*2 | 19000*2 | 2,5*2 | |
V900-4T2500 | 250 | BRU-21KW-2.5R*2 | 21000*2 | 2,5*2 | |
V900-4T2800 | 280 | BRU-24KW-2.5R*2 | 24000*2 | 2,5*2 | |
V900-4T3150 | 315 | HRU-27KW-2.5R*2 | 27000*2 | 2,5*2 | |
V900-4T3500 | 350 | BRU-20KW-2.5R*3 | 20000*3 | 2,5*3 | |
V900-4T4000 | 400 | BRU-23KW-2.5R*3 | 23000*3 | 2,5*3 | |
V900-4T4500 | 450 | HRU-26KW-2.5R*3 | 26000*3 | 2,5*3 | |
V900-4T5000 | 500 | HRU-29KW-2.5R*3 | 29000*3 | 2,5*3 |
Rated power | 0,75 kW |
Nominal output current | 2,5 A |
Supply voltage | 3 x 400 V |
Output voltage | 0 – 400 V |
Output frequency | 0 – 600 Hz |
Overload capability in ND mode – Normal Duty | 120% / 60s |
Overload in HD mode – Heavy Duty (Heavy Duty) | 150% / 60s |
Control mode V/F scalar control | ✓ |
SFVC open loop vector control mode | ✓ |
CLVC closed loop vector control mode | X |
Analog inputs | 1 |
Digital inputs | 5 |
Analog outputs | 1 |
Relay outputs | 1 |
Open collector outputs | 1 |
Integrated brake transistor | X |
EMC filter | ✓ |
+10V output | ✓ |
+24 V output | ✓ |
Input for PTC | ✓ |
Safe torque off (STO) | X |
Emergency stop (EMS) | ✓ |
Integrated Ethernet | X |
Integrated MODBUS RTU | ✓ |
PROFINET | X |
PG card for encoder | X |
PID | ✓ |
Intelligent PLC function | ✓ |
External panel connection (typically up to 30 m) | ✓ |
Protection class IP 20 | ✓ |
Protection class IP 65 | X |
Change direction of rotation via external input | ✓ |
Change direction of rotation in the control panel | ✓ |