Variable speed drive 90kW 400V V900-4T0900

Model V900-4T0900
Power 90 kW
Max. Input current 180 A
Nominal output current 167 A
Suitable motor 90 kW
Power cable cross section 70 mm²
Protection 250 A
Brake unit Optional
EMC filter Yes

In Stock

If you have any questions, please do not hesitate to contact us:

100% safe payment

Large warehouse and production in one place

Data Sheet

4T0900PDF

Dimensional drawing

4T0900PDF

Manual

V900PDF

Presentation catalog

V900PDF

3D visualization

VYBO Electric

Maximum overload capacity
Integrated, removable outer panel
Robust redesign of internal circuits
Solid metal frame
PROFINET communication
Minimized size in a compact frame

Variable speed drive 90kW 400V V900-4T0900 in stock. Variable speed drives (VSDs) from VYBO Electric – a reliable and versatile solution for your motor control needs. With a power of 90kW and a voltage of 400V, this VFD is designed to deliver outstanding performance and efficiency in various applications across the United Kingdom, from busy cities such as London, Glasgow and Birmingham to industrial centers such as Leeds and Edinburgh.

Variable speed drive 90kW V900 400V in stock

The 90kW variable speed drive 400V V900 offers a wide supply frequency range of 47 to 63 Hz, enabling compatibility with various power systems. It has a maximum frequency of 0 to 600 Hz, allowing precise control of motor speed and operation. With a speed range of 1:100 (SVC) or 1:1000 (CLVC), you have the flexibility to achieve the desired output speed for your specific application. Equipped with advanced features such as automatic torque increase or user-defined increase in the range of 0.1% to 30%, the V900 series ensures optimal engine performance and efficiency. The built-in PID controller enables a process-controlled control system that enables precise control of motor speed and torque.

Fast delivery of 90kW V900 variable speed drives throughout the United Kingdom

We deliver 90kW V900 variable speed drive quickly throughout the United Kingdom. One of the main advantages of the V900 series is its ability to automatically maintain a constant output voltage even when the supply voltage fluctuates. This ensures stable and reliable operation, protects your devices and improves overall system performance. By using powerful current vector control technology, the V900 series enables precise control of AC motor operation. It supports various input options including PG card differential input, PG card resolver and PG card rotary transformer, providing versatility and compatibility with different motor types.

Sale of Variable speed drives 90kW

At VYBO Electric, we are committed to providing our customers with competitive pricing and exceptional service. You can purchase the 90kW variable speed drive V900 in our online e-shop at an extremely reasonable price. We offer a wide range of variable speed drives and our extensive stock ensures fast delivery to cities across the United Kingdom. We pride ourselves on delivering high quality products that are built to last and perform reliably.

High-quality Variable speed drive from VYBO Electric

To provide a complete drive system solution, we offer a range of accessories and supplementary products in our e-shop, including electric motors, worm gears, inlet throttles and pressure sensors. Our user-friendly e-shop makes it easy to browse and select the products you need, and our secure checkout process ensures a seamless shopping experience. Discover the benefits of the V900 Series 90kW 400V AC drive and experience the difference it can make in your motor control applications. Order today and benefit from our fast delivery and customer-oriented service. Trust VYBO Electric for all your motor control needs and join our growing community of satisfied customers.

V900 series variable variable speed drive

With the V900 series variable speed drive, you can achieve energy savings, precise motor control and higher operating efficiency. Whether you work in manufacturing, HVAC systems, water treatment plants, or any other industry where motor control is required, the V900 Series offers the versatility and reliability you need. Experience the power of VYBO Electric’s V900 VFD and unlock the full potential of your motor-driven applications. Trust our expertise, quality products and efficient delivery to support your business success. Order your 90kW V900 frequency converter today.

Detailed Specification

Inverter model type V900 Rated power (kW). Nominal input current (A) Rated output current (A) Recommended engine power (kW)
V900-4T0900 90 180 176 90
Input voltage (V) 50/60 Hz Motor power (kW) Recommended cable cross section (mm²) Recommended circuit breaker (A)
3 phases 3×400 V 90 70 250

Table of suitable braking resistors

Frequency converter type Brake resistor Brake unit Recommended motor power (kW)
Resistance power (W) Resistance value (Ω) (≥)
V900-4T0900 15000 6,8 BRU-15kW-6,8R 90

General technical parameters for all V900 types

Power Input voltage range: 1 x 230 V AC ± 10%
Input voltage range: 3 x 400 V AC ± 10%
Input frequency Power supply frequency range: 47 to 63 Hz
Control mode V/F scalar control
SFVC open loop vector control
CLVC closed loop vector control (over 4kW)
Maximum frequency 0 – 600 Hz
Carrier frequency 0.5 kHz – 8 kHz
The carrier frequency is automatically set based on the load characteristics.
Resolution of the input frequency Digital setting 0.01 Hz
Analogue setting: maximum frequency x 0.025%
Initial torque G type: 0.5 Hz / 150% (SFVC)
G type: 0.5 Hz / 180% (CLVC)
P type: 0.5 Hz / 100%
Speed range 1:100 (SVC) 1:1000 (CLVC)
Speed stability ± 0.5% (SFVC) ± 0.2% (CLVC)
Overload capacity G type: 60s for 150% of rated current, 3s for 180% of rated current
P-Type: 60s for 120% of rated current, 3s for 150% of rated current.
Torque increase Auto boost or custom boost from 0.1% to 30.0%
V/F curve Straight V/F curve
Multipoint V/F curve
N-voltage V/F curve (multiple of 1.2-voltage, 1.4-voltage, 1.6-voltage, 1.8-voltage, modified)
V/F separation Two types: complete separation; half separation
Ramp modes Linear ramp
Four groups of acceleration/deceleration times with a range of 0.0-6500.0 s
DC braking Brake frequency: 0.0 Hz to maximum frequency
Braking time: 0.0-36.0s
Current value when braking: 0.0%-100.0%
Control in JOG mode JOG frequency range: 0.00-50.00 Hz
JOG acceleration/deceleration time: 0.0-6500.0 s
Simple PLC, multiple preset speeds Up to 16 speeds implemented via a simple PLC function or a combination of X end states
Built-in PID controller Enables a process-controlled closed-loop control system.
AVR automatic voltage regulation maintained when the supply voltage changes
Overvoltage and overcurrent regulator Current and voltage are automatically limited during operation to prevent frequent shutdowns due to over-voltage and over-current
Fast current limitation Prevents common faults due to overcurrent on AC motor
Torque and steering limitation It can automatically limit the torque and prevent the overcurrent from changing frequently during operation. Torque control can be implemented in CLVC mode.
High performance The control of the AC motor is carried out by the powerful current vector control technology.
Support for PG card Support PG card differential input, PG card resolver, PG card rotary transformer…
Safety function STO “Emergency Stop” system: In emergencies, it stops the inverter immediately after the switch J4 is activated to STO.
PTC motor warm-up test Input for thermal PTC motor protection.
Time management Time range: 0.0-6500.0 minutes
Communication protocol MODBUS RTU, PROFINET
Execute command channel Control panel / control terminals / serial communication port
You can switch between these sources in different ways
Frequency source 10 kinds of frequencies. Setting via digital, analog voltage, analog current, pulse, serial interface. You can switch between these sources with various specials.
Auxiliary frequency source 10 kinds of frequencies. Allows you to fine-tune the auxiliary frequency and frequency synthesis.
Input terminal blocks 5 digital inputs for 0.4 – 5.5 kW models
1 analog input for models up to 0.4 – 5.5 kW
6 digital inputs for models over 7.5 kW
2 analog inputs for models over 7.5 kW
Output terminal blocks 1 high speed pulse output (open collector)
1 relay output terminal for 0.4-5.5 kW models
1 analog output port for 0.4-5.5 kW models
2 output relay terminals for 7.5 – 500 kW models
2 analog output terminals for power 7.5 – 500 kW
1 high speed pulse output (open collector)
EMC (compactability) IEC 61000-4-6; IEC 61000-4-4; IEC 61000-4-11; IEC 61000-4-5
Standards EN/IEC 61800-3: 2017; C1, which is suitable for the 1st environment;
EN/IEC 61800-3: 2017; C2, which is suitable for the 1st environment;
LED display Displays parameters
Key lock and function selection It can partially or completely lock keys and set the functionality of some keys to prevent malfunctions
Protection mode Motor short circuit detection at power-on, output phase loss protection, over-current protection, over-voltage protection, under-voltage protection, over-temperature protection and overload protection.
Environmental installation Install indoors, avoid direct sunlight, salt, dust, corrosive or flammable gases, smoke and steam. Resistance to chemical pollution, class 3C3 EN/IEC 60721-3-3. Resistance to dust pollution 3S3EN/IEC 60721-3-3.
Alt. Height. Below 1000 meters above sea level. (Reduce the power level when used above 1000 meters above sea level.)
Ambient temperature -10°C – 40°C (reduce the power level when the ambient temperature is between 40°C and 50°C)
Humidity Less than 95% relative humidity, non-condensing IEC 60068-2-3
Vibrations Less than 5.9 m/s2 (0.6 g) IEC 60068-2-6
Storage temperature -20°C to + 60°C

Variable frequency drive 90kW V810 400V In stock VYBO Electric

Variable frequency drive 90kW V810 400V In stock VYBO Electric

Variable frequency drive 90kW V810 400V In stock VYBO Electric

Variable frequency drive 90kW V810 400V In stock VYBO Electric

Dimensional drawing V900 4T0900

Performance parameters of V900 series inverters

1PH / 3PH AC 230V ±15%
Inverter model type V900 Rated power (kW) Maximum input current (A) Rated output current (A) Recommended motor power (kW)
V900-2S0004 0,4 5,4 2,5 0,4
V900-2S0007 0,75 7,2 5 0,75
V900-2S0015 1,5 10 7 1,5
V900-2S0022 2,2 16 10 2,2
V900-2S0030 3 17 16,5 3
3PH / 3PH AC 400 V ±15 %
V900-4T0007 0,75 3,8 2,5 0,75
V900-4T0015 1,5 5 3,7 1,5
V900-4T0022 2,2 5,8 5 2,2
V900-4T0030 3 7,9 7,5 3
V900-4T0040 4 10 9 4
V900-4T0055 5,5 15 13 5,5
V900-4T0075 7,5 20 17 7,5
V900-4T0110 11 26 25 11
V900-4T0150 15 35 32 15
V900-4T0185 18,5 38 37 18,5
V900-4T0220 22 46 45 22
V900-4T0300 30 62 60 30
V900-4T0370 37 76 75 37
V900-4T0450 45 90 90 45
V900-4T0550 55 113 110 55
V900-4T0750 75 157 150 75
V900-4T0900 90 180 176 90
V900-4T1100 110 214 210 110
V900-4T1320 132 256 253 132
V900-4T1600 160 307 300 160
V900-4T1850 185 355 340 185
V900-4T2000 200 385 380 200
V900-4T2200 220 430 420 220
V900-4T2500 250 475 470 250
V900-4T2800 280 525 520 280
V900-4T3150 315 610 600 315
V900-4T3500 350 665 640 350
V900-4T4000 400 700 690 400
V900-4T4500 450 800 790 450
V900-4T5000 500 865 860 500
Input voltage (V) 50/60 Hz Motor power (kW) Recommended cable cross section (mm²) Recommended circuit breaker (A) Recommended input contactor (A)
V900-2S0004 1×230 V 50/60 Hz 0,4 1,5 10 9
V900-2S0007 0,75 1,5 16 12
V900-2S0015 1,5 1,5 25 18
V900-2S0022 2,2 2,5 32 25
V900-2S0030 3 2,5 40 32
V900-4T0007 3×400 V 50/60 Hz 0,75 1,5 6 9
V900-4T0015 1,5 1,5 10 9
V900-4T0022 2,2 1,5 10 9
V900-4T0030 3 1,5 16 12
V900-4T0040 4 1,5 16 12
V900-4T0055 5,5 1,5 16 12
V900-4T0075 7,5 2,5 20 18
V900-4T0110 11 4 32 25
V900-4T0150 15 4 40 32
V900-4T0185 18,5 6 50 38
V900-4T0220 22 10 80 65
V900-4T0300 30 10 80 65
V900-4T0370 37 16 100 65
V900-4T0450 45 25 100 80
V900-4T0550 55 35 160 95
V900-4T0750 75 50 160 115
V900-4T0900 90 70 250 150
V900-4T1100 110 95 250 170
V900-4T1320 132 120 400 205
V900-4T1600 160 150 400 245
V900-4T1850 185 185 400 300
V900-4T2000 200 185 500 410
V900-4T2200 220 185 500 410
V900-4T2500 250 240 630 410
V900-4T2800 280 240 630 475
V900-4T3150 315 150*2 700 620
V900-4T3500 350 185*2 800 620
V900-4T4000 400 185*2 800 620
V900-4T4500 450 240*2 1000 800
V900-4T5000 500 240*2 1000 800

Table of suitable braking resistors V900

Models with 1 x 230 V power supply (V900-2S….)
Brake unit Model Power (kW) Marker Brake resistor
Resistance power (W) Resistance value (Ω) (≥)
No V900-2S0004 0,4 80W-200R 80 200
V900-2S0007 0,75 80W-150R 80 150
V900-2S0015 1,5 100W-50R 100 100
V900-2S0022 2,2 100W-50R 100 70
V900-2S0030 3 250W-65R 250 65
Models with 3 x 400 V power supply (V900-4T….)
Brake unit Model Power (kW) Marker Brake resistor
Resistance power (W) Resistance value (Ω) (≥)
No V900-4T0007 0,75 250W-300R 250 300
V900-4T0015 1,5 300W-220R 300 220
V900-4T0022 2,2 400W-200R 400 200
V900-4T0030 3,0 500W-150R 500 150
V900-4T0040 4,0 500W-130R 500 130
V900-4T0055 5,5 500W-130R 500 130
Yes V900-4T0075 7,5 800W-90R 800 90
V900-4T0110 11 1000W-65R 1000 65
V900-4T0150 15 1500W-43R 1500 43
V900-4T0185 18,5 2000W-32R 2000 32
V900-4T0220 22 BRU-4KW-24R 4000 24
V900-4T0300 30 BRU-4.5KW-24R 4500 24
V900-4T0370 37 BRU-6KW-19.2R 6000 19,2
Possibility V900-4T0450 45 BRU-7KW-14.8R 7000 14,8
V900-4T0550 55 BRU-9KW-12.8R 9000 12,8
V900-4T0750 75 BRU-11KW-9.6R 11000 9,6
V900-4T0900 90 BRU-15KW-6.8R 15000 6,8
V900-4T1100 110 BRU-9KW-9.3R*2 9000*2 9,3*2
V900-4T1320 132 BRU-13KW-9.3R*2 13000*2 9,3*2
V900-4T1600 160 BRU-13KW-6.2R*2 13000*2 6,2*2
V900-4T1850 185 BRU-16KW-6.2R*2 16000*2 6,2*2
V900-4T2000 200 BRU-19KW-2.5R*2 19000*2 2,5*2
V900-4T2200 220 BRU-19KW-2.5R*2 19000*2 2,5*2
V900-4T2500 250 BRU-21KW-2.5R*2 21000*2 2,5*2
V900-4T2800 280 BRU-24KW-2.5R*2 24000*2 2,5*2
V900-4T3150 315 HRU-27KW-2.5R*2 27000*2 2,5*2
V900-4T3500 350 BRU-20KW-2.5R*3 20000*3 2,5*3
V900-4T4000 400 BRU-23KW-2.5R*3 23000*3 2,5*3
V900-4T4500 450 HRU-26KW-2.5R*3 26000*3 2,5*3
V900-4T5000 500 HRU-29KW-2.5R*3 29000*3 2,5*3
Rated power 90 kW
Nominal output current 176 A
Supply voltage 3 x 400 V
Output voltage 0 – 400 V
Output frequency 0 – 600 Hz
Overload capability in ND mode – Normal Duty 120% / 60s
Overload in HD mode – Heavy Duty (Heavy Duty) 150% / 60s
Control mode V/F scalar control
SFVC open loop vector control mode
CLVC closed loop vector control mode
Analog inputs 2
Digital inputs 6
Analog outputs 2
Relay outputs 2
Open collector outputs 1
Integrated brake transistor X
EMC filter
+10V output
+24 V output
Input for PTC
Safe torque off (STO) X
Emergency stop (EMS)
Integrated Ethernet X
Integrated MODBUS RTU
PROFINET
PG card for encoder
PID
Intelligent PLC function
External panel connection (typically up to 30 m)
Protection class IP 20
Protection class IP 65 X
Change direction of rotation via external input
Change direction of rotation in the control panel
Shopping Basket